| Specification |
Type: Wireless Alarm Host;
Function: Networked;
Usage: Fire;
Networking Mode: TCP/IP;
Receive Frequency: 433.92MHz;
Model: Aw-Fp101/Aw-Fp102;
Main Power: 110 VAC or 220VAC (±20%) 50Hz/60Hz;
Batteries: 2*12V,5ah Lead Acid Batteries;
Battery Low-Voltage Protection: 21V;
Number of Points on Each Loop: 250 PCS;
Temperature Range: -10 to 55°c (14~134°f);
Relative Humidity: 5 to 95%,Non-Condensing;
Network Available Options: GSM/IP/Cloud/Mobile Apps;
Fuse for AC Power: 1A/250V Glass Tube Fuse,Slow Blow,5*20mm;
Fuse for DC Power: 10A/250V Ceramics Tube Fuse Slow Blow 5*20mm;
Terminal Blocks Rating: All Terminals Rated for 12 to 18 AWG(0.75 to 2.5 M;
|
Type: Fire Alarm Repeater Panel;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥80dB;
Networking Mode: RS485;
Wiring Mode: Sub-Line System;
Product Name: Conventional Fire System Annunciator Repeater Pane;
Power Supply: 16 to 30VDC;
Standby Current: ≤15mA;
Alarm Current: ≤75mA;
Relay Contact Capacity: 2A@24VDC;
Buzzel Level: 80dB@1m;
Communication Mode: RS485 Wire;
Relay Output: Fire & Fault;
Display Zone: 16 Conventinal Zones;
LED Indicators: Yes;
Control Buttons: Yes;
Material: ABS;
Wire Inlet: 1/2 Inch;
Matched Host: as-Bfp, as-Afp Series Panel;
Application: Office, Factory, Warehouse, Apartment, Hotel, etc.;
|
Type: Fire Alarm Panel;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥90dB;
Wiring Mode: 2 Wires System;
Product Name: 4 / 8 / 16 Zones Fire Alarm Control Panel System;
Main Power Supply: 90 to 270VAC, 50Hz;
Backup Battery: 2 PCS Lead Acid Battery;
Power Supply Rating: 3 AMPS @ 24VDC;
Initiating Device Circuits: 4 - 16 Detection Zones;
Notification Appliance Circuits: 1 - 4 Sounder Lines;
Zone Capacity: 25 - 30 Detectors;
Disabled Function: Yes;
Emergency Evacuate Function: Yes;
Relay Output: Fire & Fault & Supervisory;
Relay Contact Rating: 2A & 30VAC, Resistive;
Mode Selection: Auto & Manual;
Standard: En54-2 & En54-4;
Dimension: 440X370X100 mm;
Application: Office, Factory, Warehouse, Apartment, Hotel, etc.;
|
Type: Fire Alarm Host;
Function: Networked, RS485 or RS232;
Usage: Fire Alarm Control;
Alarm Volume (within 1m): ≥80dB;
Networking Mode: Can Bus;
Receive Frequency: Addressable Fire Alarm;
Wiring Mode: Non-Polarity 2 Wired;
Applications: Building, Factory,Hotel, Housing;
Capacity: Maximum 508;
Installation: Wall Mounted;
Loops: Maximum 2 Loops;
|
Type: Fire Alarm Host;
Function: Networked, RS485 or RS232;
Usage: Fire Alarm Control;
Alarm Volume (within 1m): ≥80dB;
Networking Mode: Can Bus;
Receive Frequency: Addressable Fire Alarm;
Wiring Mode: Non-Polarity 2 Wired;
Applications: Building, Factory,Hotel, Housing;
Capacity: Maximum 508;
Installation: Wall Mounted;
Loops: Maximum 2 Loops;
|