| Specification |
Type: Fire Alarm Panel;
Function: Networked;
Usage: Fire, Smoke;
Alarm Volume (within 1m): ≥90dB;
Wiring Mode: 2 Wires System;
Product Name: Fire Alarm Panel;
Main Power Supply: 90 to 270VAC, 50Hz;
Backup Battery: 2 PCS Lead Acid Battery;
Power Supply Rating: 3 AMPS @ 24VDC;
Initiating Device Circuits: 4 - 16 Detection Zones;
Notification Appliance Circuits: 1 - 4 Sounder Lines;
Zone Capacity: 25 - 30 Detectors;
Disabled Function: Yes;
Emergency Evacuate Function: Yes;
Relay Output: Fire & Fault & Supervisory;
Relay Contact Rating: 2A & 30VAC, Resistive;
Mode Selection: Auto & Manual;
Standard: EN54-2 & EN54-4;
Dimension: 440X370X100 mm;
Application: Office, Factory, Warehouse, Apartment, Hotel, etc.;
|
Type: Fire Alarm Host;
Function: Networked;
Usage: Auto, Fire, Smoke;
Alarm Volume (within 1m): ≥90dB;
Networking Mode: TCP/IP;
Receive Frequency: 229.95MHz;
Wiring Mode: Bus System;
Approvals: Lpcb / CE-CPR;
No. of Loop: 1 Loop;
Material: Flat Sheet Metal;
Weight: 16.70kg;
Protection: 4kv Surge Protection (Built-in);
Input Voltage: 100-240VAC+10%-15%, 50/60Hz;
Indicator: 24 LED Status/30 Zone Indicators;
Network Panel to Panel: 128 Panels-Single Can Bu(Loop);
System Capacity Memory[Non-Volatile]: 1000 Fire Events, 10,000 General Event;
Protocol/Addressing: T&a, Value Range From 1 to 254;
Programmable Relays: 2 Circuits: Normally Open/Close;
Programmable Input: 1 Circuit: Power Limited 24VDC;
Programmable Aux Power: Limited 19-28VDC;
Fixed Outputs: 1 Circuits: Power Limited 18-28VDC;
Display: 7'' TFT Touch Screen;
|
Type: Wireless Alarm Host;
Usage: Fire, Smoke;
Main Power: 110 VAC or 220VAC (±20%) 50Hz/60Hz;
Battery Low-Voltage Protection: 21V;
Temperature Range: -10 to 55°c (14~134°f);
Fuse for AC Power: 1A/250V Glass Tube Fuse, Slow Blow,5*20mm;
Terminal Blocks Rating: All Terminals Rated for 12 to 18 AWG (0.75 to 2.5m;
Number of Points on Each Loop: 128 PCS;
Relative Humidity: 5 to 95%, Non-Condensing;
Batteries: 2*12V, 2.3A Lead Acid Batteries;
|
Type: Wireless Alarm Host;
Usage: Fire, Smoke;
Main Power: 110 VAC or 220VAC (±20%) 50Hz/60Hz;
Battery Low-Voltage Protection: 21V;
Temperature Range: -10 to 55°c (14~134°f);
Fuse for AC Power: 1A/250V Glass Tube Fuse, Slow Blow,5*20mm;
Terminal Blocks Rating: All Terminals Rated for 12 to 18 AWG (0.75 to 2.5m;
Number of Points on Each Loop: 128 PCS;
Relative Humidity: 5 to 95%, Non-Condensing;
Batteries: 2*12V, 2.3A Lead Acid Batteries;
|
Type: Fire Alarm Host;
Usage: Fire, Smoke;
Mains Supply: 110V/230V* AC (-15%, +10%),50Hz*/60Hz;
Operating Voltage: 20 ~ 28VDC;
Power Rating: Imin=0.15A; Imax.a=1.15A; Imax.B=1.65A;
Max. Battery Supply Current: 3A (When The Mains Is Disconnected);
Battery Capacity, Type: Np7-12 for 7ah VRLA(Yuasa);
Np7-12 for 7ah VRLA(Yuasa): 1Ω;
Battery Fuse: F6al250V;
Recommended Mains Cable: Standard/Black Mains Cable, Cable Size 0.75mm2;
|