| Specification |
After-sales Service: Remote Teach,Timely Communication to Solve Problem;
Warranty: 1 Years;
Appliance: Food Analysis;
Gaspath System: Double;
Detector: UV-Vis Dual-Wavelength Detector;
Stationary Phase: Liquid Solvent;
Mobile Phase: Liquid;
Chromatography Type: Liquid Chromatography;
Chromatographic Column Type: Preparative Column;
Chromatographic Column Length: 650mm;
Chromatographic Column Diameter: 50mm;
Working Pressure: 10MPa;
Liquid Contact Material: 316L/PTFE;
Sieve Plate Size & Pore Size: 316L/3μm;
Working Temperature: 5-60℃;
Wavelength Accuracy: ±1nm;
Control Mode: RS232 or LAN;
Detection Range: (0~5)Au;
High-Pressure Seal Ring: Imported;
Distribution Mode: Forced Distribution;
|
After-sales Service: 24/7. All Time Zones Friendly;
Warranty: 1year;
Appliance: Transformer Oil;
Gaspath System: Three;
Detector: TCD and FID;
Energy Resolution: ≤7%;
Stationary Phase: Liquid Solvent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 0.2~0.5mm;
Product Name: Oil Gas Chromatograph;
Voltage Range: 0.5~10kv;
Test Current Range: 10μa~1A;
Power Factor: 0.02 < Cos φ < 0.1;
Current Range: 0.5A ~ 15A (Internal), 0.5A ~ 50A (External);
Frequency Measuremen: 45 ~ 65Hz;
Ambient Temperature: -10°c to 50°c;
Ambient Humidity: ≤85%rh, Non-Condensing;
Operating Power Supply: AC220V ±10%;
Use: Testing the Gas Analysis;
|
After-sales Service: 24/7. All Time Zones Friendly;
Warranty: 1year;
Appliance: Transformer Oil;
Gaspath System: Three;
Detector: TCD and FID;
Energy Resolution: ≤7%;
Stationary Phase: Liquid Solvent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 0.2~0.5mm;
Product Name: Oil Gas Chromatograph;
Voltage Range: 0.5~10kv;
Test Current Range: 10μa~1A;
Power Factor: 0.02 < Cos φ < 0.1;
Current Range: 0.5A ~ 15A (Internal), 0.5A ~ 50A (External);
Frequency Measuremen: 45 ~ 65Hz;
Ambient Temperature: -10°c to 50°c;
Ambient Humidity: ≤85℅rh, Non-Condensing;
Operating Power Supply: AC220V ±10%;
Use: Testing the Gas Analysis;
|
After-sales Service: 24/7 Online Service;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Single;
Detector: TCD;
Energy Resolution: ≤7%;
Spectrometer Detector: SDD;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 20~40mm;
Product Name: Oil Gas Chromatograph;
Voltage Range: 0.5~10kv;
Test Current Range: 10μa~1A;
Power Factor: 0.02 < Cos φ < 0.1;
Current Range: 0.5A ~ 15A (Internal), 0.5A ~ 50A (External);
Frequency Measuremen: 45 ~ 65Hz;
Ambient Temperature: -10°c to 50°c;
Ambient Humidity: ≤85℅rh, Non-Condensing;
Operating Power Supply: AC220V ±10%;
|
After-sales Service: 24/7 Online Service;
Warranty: 1 Year;
Appliance: The Analysis of Environmental Samples;
Ray Type: Gamma Ray Spectrometer;
Gaspath System: Single;
Detector: TCD;
Energy Resolution: ≤7%;
Spectrometer Detector: SDD;
Stationary Phase: Solid Adsorbent;
Mobile Phase: Gas;
Chromatography Type: Gas Chromatography;
Chromatographic Column Type: Convetional Analytical Column;
Chromatographic Column Length: 10~30cm;
Chromatographic Column Diameter: 20~40mm;
Product Name: Oil Gas Chromatograph;
Voltage Range: 0.5~10kv;
Test Current Range: 10μa~1A;
Power Factor: 0.02 < Cos φ < 0.1;
Current Range: 0.5A ~ 15A (Internal), 0.5A ~ 50A (External);
Frequency Measuremen: 45 ~ 65Hz;
Ambient Temperature: -10°c to 50°c;
Ambient Humidity: ≤85℅rh, Non-Condensing;
Operating Power Supply: AC220V ±10%;
|