| Specification |
After-sales Service: Response in 12 Hours;
Warranty: 1 Year;
Test Standard: IEC 60331,BS 6387;
Power Supply: AC 380V 3-Phase, 50/60Hz, 30A;
Dimension of Controller: 650 (D) X400 (W) X1200 (H);
Dimension of Test Unit: 1,600(W)×850(D)×1,900(H)mm;
Weight: 300kg;
Exhuast: Minimum 15m³/ Min;
Display: LCD;
Color: Grey;
Timing Range: 0 to 9 Hours 99 Minutes 99 Seconds;
Application: Cable and Wires Testing;
Flame Temperature Range: 600° ~ 1000 °;
Load Capacity of Sample Tray: 30kg;
Hammering Cycle (Time): 30 ± 2s / Time;
Length of Sample: 400mm;
Sprinkler Water Pressure: 250 ~ 350kpa;
|
After-sales Service: Life Long Term Technical Support;
Warranty: 1 Year;
Name: Karl Fischer Titrator;
Titration Method: Microprocessor Controlled Titration.;
Electrolytic Current Output: 0-400mA Automatic Control.;
Display System: LCD Color 7 Inch Large Screen Display.;
Man-Machine Dialogue Mode: Touch Screen Input.;
Sensitive Valve: 0.1ugh2o.;
Accuracy: 10ug - 1mgh2o Is ±3ug,1mgh2o Above, 0.3%;
.Power Consumption: Less Than 100W.;
|
After-sales Service: Life Long Term Technical Support;
Warranty: 1 Year;
Name: Kinematic Viscometer;
Power Supply: AC(220±10%)V, 50Hz;;
Total Power Consumption: ≤1800W;;
Temperature Range: Ambient to 100.0℃;
Temperature Control Accuracy: ±0.01℃;
Bath Capacity: 20L;
Timing Range: 0.0s~9999.9s;
Timing Accuracy: ±0.05% Within 60min;
Stirring Motor: 1200 Rpm;
Working Condition: 15℃~35℃, Rh: ≤85%;
Temperature Sensor: Rtd, PT100;
.Net Weight: 42kg.;
|
After-sales Service: Life Long Term Technical Support;
Warranty: 1 Year;
Name: Kinematic Viscometer;
Power Supply: AC(220±10%)V,50Hz;
Total Power Consumption: ≤2100W;
Temperature Sensor: PT1000;
Temperature Range: 15℃~120℃;
Temperature Resolution: 0.001℃;
Temperature Control Accuracy: ±0.04℃;
Timing Accuracy: ±0.1s,Resolution Ratio 0.01s;
Sample Quantity: 2 PCS;
Display Mode: Colored Gui Touch Screen.;
Net Weight: 99kg;
|
After-sales Service: Yes;
Warranty: 1 Year;
Power Source: AC380V/220V±15%/50Hz±5%;
Rated Output Voltage: 0-1000kv (AC RMS) and Below;
Output Frequency: 20-300Hz;
Resonant Voltage Waveform: Pure Sine Wave, Waveform Distortion Rate <1.0%;
Continuous Operation Time: up to 60 Minutes at Full Power;
Quality Factor: 30-90;
Output Waveform: Sine Wave;
Frequency Adjustment Accuracy: 0.01Hz, Instability ≤0.05%;
Standard: ISO/IEC;
Customized Support: OEM, ODM, Obm, Software Reengineering;
Product Name: AC Resonant Test System;
Frequency Converter: Customizable;
Resonant Reactor: Customizable;
Divider: Customizable;
Output Voltage: Customizable;
|