| Specification |
After-sales Service: Life Time Support;
Warranty: 1 Year or Extended;
Type: Universal Testing Machine;
Accuracy Grade: RMS 1.5;
Display: Touch Screen;
Power Source: 220V/380V,10 %Single Phase, 50Hz;
Frequency: 20Hz-300Hz;
Waveform: Sine;
Protection: Over-Current, Over-Voltage,Flash-Over;
Mode: Automatic and Manual Operation Mode;
Print: Support;
Tested Object: Cable, Gis, Transformer, Gil,Ect;
Test Time: 1hours or Customized;
Using Place: Outdoors or Indoors;
Partial Discharge: PC Less Than 10PC Support;
Cabliration Report: Factory Report or The Third -Party Support;
|
Product Name: Transformer Dielectric Loss and Tan Delta Tester;
Test Standard: IEC60076;
Max Output Voltage: 10kv (12kv for Choice);
Maximum Current: 200mA;
Capacity: 2000va;
Measuring Range: Cx: 15PF<Cx<300NF;
CVT Test: Cx <300 NF;
CVT Range: 10~10000;
Measurement Error: Capacitor Value: 1%Rdg+5PF , Tangent Delta: 1%Rdg+;
Function: Transformer Dissipation Factor Tester;
Accuracy: 0.5%;
Testing Voltage Setting Resolution: 0.5kv;
Test Mode: Fully Automatic;
Application: Power Plant;
Output Voltage: AC 0.5kv~10kv;
|
Max Diameter of Workpiece: Φ1.0-Φ20mm;
Mass Scope of Workpiece: Each 10kg;
Type: Cable Veyor Test Equipment;
Load Way: Electronic Load;
Display: Digital;
Control: Manual Control;
Weight: 1400kg;
Power Source: AC380V;
|
Type: Universal Testing Machine;
Accuracy Grade: 0.1;
Load Way: Electronic Load;
Display: LCD;
Control: Computer Control;
Weight: >2000Kg;
Power Source: AC380V;
Test Capacitive: 5000kVA or at Option;
No Load Current and No Load Losses: Power Analyzer;
Induced Voltage Test: Dvdf Test Set;
Measurement of Transformer Ratio: TTR Tester;
Measurement of Winding Resistance: DC Winding Resistance Tester;
Applied Voltage Test: Power Frequency Withstand Voltage AC Hipotest Set;
Insulation Resistance Measurement: Portable Megohm Meter;
Control Mode: Manual/PLC at Customized;
Test Items: TTR, Dvdf, Resistance, Hipot and Customized;
OEM: Support;
Test Standard: IEC 60076;
Power Supply Controlling: 3 Phase 4 Wires;
Protection: Full Functions;
Test Object: Distribution Transformers Power Transformers;
Temperature Rise Test: Regulator and Ohmmeter with Tempera Rise Function;
|
Type: Universal Testing Machine;
Accuracy Grade: 0.1;
Load Way: Electronic Load;
Display: LCD;
Control: Computer Control;
Weight: >2000Kg;
Power Source: AC380V;
Test Capacitive: 5000kVA or at Option;
No Load Current and No Load Losses: Power Analyzer;
Induced Voltage Test: Dvdf Test Set;
Measurement of Transformer Ratio: TTR Tester;
Measurement of Winding Resistance: DC Winding Resistance Tester;
Applied Voltage Test: Power Frequency Withstand Voltage AC Hipotest Set;
Insulation Resistance Measurement: Portable Megohm Meter;
Control Mode: Manual/PLC at Customized;
Test Items: TTR, Dvdf, Resistance, Hipot and Customized;
OEM: Support;
Test Standard: IEC 60076;
Power Supply Controlling: 3 Phase 4 Wires;
Protection: Full Functions;
Test Object: Distribution Transformers Power Transformers;
Temperature Rise Test: Regulator and Ohmmeter with Tempera Rise Function;
|